Laboratory Medicine
Test catalogue
Gamma-Glutamyl Transferase, Fluid | |
---|---|
Test NameGamma-Glutamyl Transferase, Fluid |
|
Specimen Type / RequirementsContainer Type = Sterile Container Minimum Testing Volume = 1ml Body Fluid |
|
Specimen HandlingCollection Instructions: Body fluid collected in red top vacutainer or sterile urine container. Indicate source of fluid Write your initials, date and time of collection on the collection label. Stability: Stable at room temperature for 1 week, refrigerated for 1 week and frozen -15 to -20°C for 2 months Transportation: Transport at room temperature ASAP. Spin if sample time of collection to time sample get to lab exceeds 2hrs Laboratory Staff Instructions: Centrifuge to remove cellular material. Sample Rejection Criteria: Unlabeled, leaking and/or non sufficient quantity (Not Sufficient Quantity) will be rejected |
|
Required Documentation |
|
Turnaround Time (TAT)1 hour stat/trauma, 2 hours routine |
Test Utilization |
Reference ValueSee Report |
|
Test CodeFGGT |
MethodologySpectrophotometric |
Testing LocationSMH-Biochemistry |
Other InformationLast Updated: May 7th, 2021
|