Test NameAlbumin Random Urine |
|
Specimen Type / RequirementsContainer Type = Small orange cap container Minimum Testing Volume = 5 mL urine |
|
Specimen HandlingCollection Instructions: Collect Random Urine in a small orange cap container. Indicate date and time of Collection Laboratory Staff Instructions: Create an aliquot from the sample and Centrifuge before placing on automation line using the bypass rack. Stability: Urine is stable at room temperature for 4 h, refrigerated for 1 week and frozen for 3 months (avoid freeze thaw cycles). Transportation: Send sample to core lab ASAP Sample Rejection Criteria: Urine collected with acid / alkaline or leaking specimen will be rejected |
|
Required Documentation |
|
Turnaround Time (TAT)1 Day |
Test UtilizationRoutine |
Reference Value< 20 mg/L |
|
Test CodeUMA |
MethodologyImmunoturbidimetry |
Testing LocationSMH-Biochemistry |
Other InformationLast Updated: June 06, 2019
|